EasyManua.ls Logo

Klein 3900 Series - System X000 Sub-Bottom Profiler (SBP) Commands

Klein 3900 Series
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B-22 APPENDIX B TPU Software Interface and Control
Series 3900 Sonar System Operations and Maintenance Manual 11214510, Rev. 02
$XMdddd:
Selects the transmitter mask. Each transmitter board is
comprised of 16 transmitters. Each transmitter can be
individually masked. Each bit in the hex value dddd
corresponds to a transmitter. For example $XM0001 would
enable only the first transmitter. Likewise $XMF00F would
enable the upper four and lower four transmitters. The
default is $XMFFFF (all on).
B.6.9 System x000 Sub-Bottom Profiler (SBP) Commands.
System x000 Sub-bottom Profiler (SBP) Commands.
$SGd: Selects the Sub Bottom Preamp Gain where d = 0 is low and
d = 1 is high. Default is 1.
$SEd: Enables (d=1) or disabled (d=0) the Sub Bottom Tx. Default
is 1.
$SWd: Selects the Sub Bottom Tx waveform where d = 0 - 15.
Default is 0.
$STd: Selects the Sub Bottom test mode where d = 0 - 6. The test
modes are as follows:
d = 0: Normal mode: RX data is sent.
d = 1: Reserved.
d = 2: Reserved.
d = 3: Generate a sawtooth waveform by holding the low
12 bits at 0xFFF, and incrementing a 12-bit
counter every sample time to drive the high
12 bits.
d = 4: Reserved.
d = 5: Send the static data pattern 1-2-3-A-B-E for every
24-bit sample.
d = 6: Redirect selected TX waveform to uplink.
Decimate the sample rate as required (8:1) and
assign to MS 8 bits of each 24-bit sample. (Low
16 bits 0x0000).

Table of Contents