7.10 Electrical system
Troubles & possible causes Fixing methods
(1) Accumulator doesn’t have enouph power
Pillar plate sulfurized seriously
There is something wrong with the
generator or regulator
Wire connect unwell
Charge again and remove the
sulfuration
Check the generator or regulator
Check and repair
(2) The temperature of the accumulator is too
high
Current is too large Check and adjust
(3) The generator does not generate power
Rotor coil broken Check and repair
(4) The generator does not charge enough or
charge unsteadily
Transmission V belt looses, making
generator rate decline
oint of the wire looses
Carbon is broken
Regulator is damaged
Adjust
Fasten the bolt
Check and repair
Check and repair
(5) There is a noise in the generator
The generator is installed incorrectly
Bearing of generator is broken
The rotor meet with the stator or
something else
Reinstall
Replace
Repair
(6) The starter motor does not work
The wire is broken or wire joint dosen’t
connect correctly
The fuse is broken
Battery volume is insufficient
Weld or replace the wire, clean
the dirt and fasten the bolt
Replace
Charge the battery