CoolAdd
®
Manual / Bedienungsanleitung
CoolAdd 01.998.350.0 iss ue a page / Seite 1/59
Manual
CoolAdd
®
Retrofit Heat Exchanger
for Existing Server Cabinets
Effective cooling capacity 8 kW
Bedienungsanleitung
Cool Add
®
Nachrüst - Wärmetauscher
für vorhandene Schaltsch ränke
Nutzkühlleistung 8 KW
(ab Seite 31)
date / Datum issue / Ausgabe author / erstellt reviewed / geprüft
2006-02-09 01.998.350.0 issue / Ausgabe b Carsten Dietze Heiko Ebermann
Question and Answer IconNeed help?

Do you have a question about the Knurr CoolAdd and is the answer not in the manual?

Knurr CoolAdd Specifications

General IconGeneral
BrandKnurr
ModelCoolAdd
CategoryAccessories
LanguageEnglish

Summary

1. Safety

1.1 Work safety symbols

Symbols indicating potential hazards or providing safety guidance.

1.2 Safety instructions

Critical guidelines for safe operation and installation of the unit.

2. Operating conditions

3. Description

3.1 General function

Explains the CoolAdd's role as a retrofit heat exchanger for server cabinets.

3.2 Principle of cooling

Illustrates and describes the cooling process with a diagram.

3.3 Dimensions

Provides detailed physical size and mounting specifications for the unit.

3.4 Technical Data

Lists comprehensive technical specifications and performance metrics.

3.5 Control

Details how the unit's temperature and fan operations are managed.

4. Storage and transportation

5. Installation and commissioning

5.1 Preparation for installation

Outlines necessary checks and preparations before installing the CoolAdd.

5.2 Positioning the units

Guidance on aligning the server cabinet and mounting the CoolAdd unit.

5.3 Cooling water connection

Instructions for connecting the unit to the cooling water supply network.

5.4 Condensed water connection

Procedure for connecting the drain for condensed water.

5.5 Electrical connection

Steps for connecting the unit to the electrical power supply.

5.6 Sealing of cabinet

How to seal the gap between the CoolAdd and cabinet for optimal cooling.

6. Service and maintenance

7. Dismantling and disposal

8. Customer service, manufacturer's address

9. Appendix

9.1 Quality requirements for water used in CoolAdd

Specifies the required quality standards for cooling water.

9.2 Checklist for unit installation

A checklist to verify the correct completion of installation steps.

9.3 Commissioning certificate

Template for documenting the successful commissioning of the unit.

9.4 Wiring scheme