EasyManua.ls Logo

Ko Propo EX-NEXT - TLMY Telemetry - Battery Fail-Safe; Battery Fail-Safe Configuration; Voltage Level Settings

Ko Propo EX-NEXT
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
BT F/S Battery fail safe
Set the battery fail-safe.
TLMY Telemetry
TELEMETRY
RELICSRESP
RFMODE
BT F/S
TIMER タイマー
TIMER
OFF
OFF
TIMER START
TRG START
LAP HISTORY
START/STOP KEY
LAP KEY
BATTERY FAIL SAFE
CURREN :
ALERT :
FAIL SAFE :
ALERT MODE: VIBRATOR
MINIMUM :
MAXIMUM :
0.0V
5.8V
0.0V
0.0V
6.0V
CLR
CURRENT
(Current battery voltage of receiver)
ALERT
(Aleart start voltage setting)
Setting Range
3.0 - 8.5V(Default : 5.5V)
FAIL SAFE
(Battery fail safe start voltage setting)
Setting Range
3.0 - 8.5V(Default : 5.0V)
ALERT MODE
(Alert mode setting)
Setting Range
VIBRATOR, BUZZER VIBRATOR + BUZZER
(Default : VIBRATOR)
MINIMUM
(Minimum voltage of receiver battery)
MAXIMUM
(Maximum voltage of receiver battery)
CLR
(Read data again)
The battery fail-safe function is a function that can be set to
automatically decelerate or brake when the voltage of the receiver
battery falls below the set voltage.When the fail-safe function is
activated, the automatically set servo is operated to an arbitrary
position (the position set by the fail-safe function on p.21).
When the voltage is restored, the battery fail-safe function will be
automatically canceled.
* The battery fail-safe function is intended to prevent accidental
use of a damaged receiver battery.
We do not recommend using it as a protective function when
the normal receiver battery is exhausted.
* This is a function exclusively for engine cars. Do not use the
battery fail-safe function in an electric car.
BT F / S can be used to check the ESC voltage.
You can check the minimum voltage and maximum voltage and
use it to judge whether the ESC BEC is normal.
P
P
TIMER タイマー
TIMER
OFF
OFF
TIMER START
TRG START
LAP HISTORY
START/STOP KEY
LAP KEY
BATTERY FAIL SAFE
CURRENT :
ALERT :
FAIL SAFE :
ALERT MODE: VIBRATOR
MINIMUM :
MAXIMUM :
8.1V
OFF
7.1V
8.2V
5.5V
CLR
TIMER タイマー
TIMER
OFF
OFF
TIMER START
TRG START
LAP HISTORY
START/STOP KEY
LAP KEY
BATTERY FAIL SAFE
CURRENT :
ALERT :
FAIL SAFE :
ALERT MODE: VIBRATOR
MINIMUM :
MAXIMUM :
8.1V
6.0V
7.1V
8.2V
5.8V
CLR
TIMER タイマー
TIMER
OFF
OFF
TIMER START
TRG START
LAP HISTORY
START/STOP KEY
LAP KEY
BATTERY FAIL SAFE
CURRENT :
ALERT :
FAIL SAFE :
ALERT MODE:
MINIMUM :
MAXIMUM :
8.1V
6.0V
5.8V
7.1V
8.2V
VIBRATOR
CLR
Reference value : Life 5.2V Lipo 6.0V
VIBRATOR or BUZZER will notify you when the voltage drops
below the set voltage.
Reference value : Life 5.0V Lipo 5.8V
If the voltage drops below the set voltage, the fail-
safe function will operate.
VIBRATOR(recommended)
Or set it to BUZZER.
This setting is reected in the ALERT operation.

Table of Contents