EasyManua.ls Logo

Kodak Magnus VLF Q2400 - Page 6

Kodak Magnus VLF Q2400
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Operation
Turn on the platesetter
1
These operations are required for some of the
maintenance procedures below.
Turn o the platesetter
2
Reset the platesetter
3
Maintenance procedure Work to be done How often
Date work
completed
Exterior surfaces Clean
Weekly
Edge detection strip
1
4
Clean
Six months or
as needed
Plate roller
1
5
Clean
Rear fan filters
1
6
Replace
328-00036
Punch chip collection box
1, 3
Empty
Compressed air supply
(particulate filter only)
1
8
Replace
328-00001
Power box intake air filter
1
9
Replace
55-1292A
Heat exchanger intake air
filter
1, 2
10
Replace
55-1293A
As needed
Debris removal filter
1
Replace
MDRC: 252-11119A
UDRC: 57-8792D
As needed
1
This procedure is included in this visual reference guide.
2
This procedure applies only to models with the heat exchanger option.
3
This procedure applies only to models with the punch option.
For more information, see the Print Console User Guide.
Operator maintenance schedule
4
5
1
2
7
8
10
9
3
6
7
11
11

Other manuals for Kodak Magnus VLF Q2400

Related product manuals