6
Turn o the compressed air.
0 psi
Replacing the air supply particulate filter
1
3 4
Unscrew the bowl. Pull the tab down and turn
the bowl 45° to the left.
6
Clean the inside of the bowl with
warm water and mild soap.
7
Replace the O-ring, if necessary.
8
Reattach the bowl. Push the bowl up
and turn it to the right until it clicks.
9
Turn on the compressed air.
100–125 psi
5
Install the new filter.
Particulate filter
Bowl
Ta b
CAUTION: To prevent possible serious injury
from flying parts or loud noise caused by
the release of high-pressure air during filter
replacement, confirm that the compressed air
supply is turned o before installing the new
air supply particulate filter.
Particulate filter
Open the rear hood:
a
In Print Console, unlock
the panels.
b
Turn the handle counterclockwise and lift the hood.
2
Use a slotted screwdriver
to loosen the two screws
that secure the rear panel
to the platesetter.
Close the rear panel, tighten the
screws, and close the rear hood.
10
In Print Console, lock the panels.