2-18 A-61627 November 2008
Black and White
Adjustment option
Black and White Adjustment — allows you to change the Contrast
and Threshold values. This option is only available if your Scan As
selection is Black and White.
If you select Best (iThresholding) on the Scan As screen, only the
Contrast value can be changed.
If you select Normal (ATP), both Contrast and Threshold can be
changed.
Contrast adjusts the difference between black and white, thereby
making an image sharper or softer. In a low contrast setting, the
difference between black and white is small, so the image is softer. In a
high contrast setting, the difference between black and white is large,
so the image is clearer. Select a contrast value from 1 to 100. The
default is 50.
Threshold — converts a grayscale image to a black and white image.
The thresholding values range from 0 to 255. The default is 90. A low
threshold value produces a lighter image, and can be used to subdue
backgrounds and subtle, unneeded information. A high threshold value
produces a darker image, and can be used to help pick up faint images.
1. When you select Contrast or Threshold, the Contrast (or
Threshold) screen will be displayed:
2. Use the Up and Down arrows to adjust the value, then click the
button to the left of the number to save the new value.