TP-6734 5/1020 Section 2 Operation
Button Button Function
RUN Starts the generator set. The engine start
time delay is ignored.
OFF Shuts down the generator set. The
cooldown time delay is ignored.
During the engine crank cycle, pressing
OFF will stop the crank cycle.
Press and hold for 3 seconds to view event
history. See Section 2.11.
AUTO Places the generator set in Auto mode.
See Figure 2-5.
DOWN
arrow
(RDC) or
EXERCISE
(DC)
Starts an unloaded exercise. Press during
test or exercise to change from unloaded to
loaded.
Select
RDC only. Used to change parameter
settings. Password-protected. Contact
your distributor/dealer if necessary.
UP arrow
Figure 2-4 Pushbutton Operation
2.5.3 LED Indicators
LEDs above the RUN, OFF, and AUTO buttons indicate
the mode of operation as shown in Figure 2-5.
Mode LED Indication Description
RUN RUNLEDison The generator set was started by pressing the RUN button. Generator set is
running. Remote start and stop commands are ignored.
OFF OFF LED lights for 2
seconds, then flashes
every 2 seconds.
The OFF button was pressed. Generator set and controller are off. Remote
start/stop commands have no effect.
AUTO AUTOLEDison Automatic mode. Generator set will respond to engine start and stop commands
from the controller or an ATS. Time delays operate as described in Section 2.6.
Figure 2-5 Operation Modes and LED Indicators