Disassembly/Reassembly 8-9TP-5606 6/02
13. Remove the screw and flat washer securing the
exciter armature using a 9/16-inch wrench.
Remove the exciter armature from the rotor
assembly. See Figure 8-26.
1
2
1. Screw 2. Exciter Armature
Figure 8-26. Removing the Exciter Armature
14. Remove the bolts from the two generator
vibromounts using a 1/2-inch wrench. See
Figure 8-27.
1
1. Vibrmount Bolt
Figure 8-27. Removing the Vibromount Bolts
15. Using a hoist, raise the alternator end of the
generator. See Figure 8-28.
NOTE
Use a hoist with a lifting capacity of one-half ton or
greater.
16. Place a wood block under the flywheel housing and
lower generator until block supports alternator.
1
1. Sling
Figure 8-28. Using Hoist to Raise Generator Set
17. Remove the four overbolts securing the end
bracket using a 17-mm socket and ratchet. See
Figure 8-29.
1
1. Overbolt
Figure 8-29. Removing the Overbolts
18. Remove the end bracket by bumping the end
bracket flanges with a soft rubber mallet. See
Figure 8-30.

Table of Contents

Other manuals for Kohler 15CCFOZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 15CCFOZ and is the answer not in the manual?

Kohler 15CCFOZ Specifications

General IconGeneral
BrandKohler
Model15CCFOZ
CategoryInverter
LanguageEnglish

Related product manuals