EasyManua.ls Logo

Kohler 20EKOZD - Page 67

Kohler 20EKOZD
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TP-6953 7/19 67Section 2 Operation
SiteTecht Parameter
Write
Access
Units
Decision-Maker
r
3500
User Interface
Notes
Engine Crank Pause Delay Always s Crank Pause Delay: ##s The length of time for the
off-period of the crank
cycle
Engine Number Of Crank Cycles Stopped Crank Cycles Limit: ## The number of crank
cycles before an over
crank fault is indicated
Genset Protection
After Crank Disconnect Fault Inhibit Delay Not supported for these models.
Genset Low Battery Voltage Warning Delay None s
Genset High Battery Voltage Warning Delay None s
Genset Low Battery Voltage Warning Limit Always % Percentage of System
Battery Voltage that the
battery voltage must drop
below for a Low Battery
voltage condition to be
indicated
Genset High Battery Voltage Warning Limit Always % Percentage of System
Battery Voltage that the
battery voltage must
exceed for a High Battery
voltage condition to be
indicated
Genset Battery Low Cranking Voltage Warning Delay None s
Genset Battery Low Cranking Voltage Warning Limit None % Percentage of System
Battery Voltage that the
battery voltage must drop
below during cranking for
a Low Cranking Battery
condition to be indicated
Engine Protection
Engine Low Coolant Level Shutdown Delay None s
Engine Low Oil Pressure Warning Delay Locked s
Engine Low Oil Pressure Shutdown Delay Locked s
Engine Locked Rotor Shutdown Delay Always s The length of time for the
starter to be engaged
with no engine rotation
detected, before a fault is
indicated
ECM Communication Loss Shutdown Delay Not supported for these models.
Genset Low Engine Speed Shutdown Limit Always % Percentage of nominal
engine speed that the
engine must drop below
for an under speed
condition to be indicated
Genset High Engine Speed Shutdown Limit Always % Percentage of nominal
engine speed that the
engine must exceed for
an overspeed condition
to be indicated
Engine Oil Pressure Protectives Enabled Locked
Engine Low Oil Pressure Inhibit Delay Locked s The time, after crank
disconnect, before the
protectives are
monitored; if 0,
protectives are monitored
even when the engine is
stopped
Engine Low Oil Pressure Warning Limit Locked kPa
Engine Low Oil Pressure Shutdown Limit Locked kPa
Engine Oil Pressure Deadband Locked kPa
Generator Protection
Loss Of AC Sensing Shutdown Delay None s
Genset Low Voltage Shutdown Delay Always s Undervoltage Delay: ##s Thetimethatthe
generator voltage must
be in an under voltage
condition before a fault is
indicated
Genset High Voltage Shutdown Delay Always s Overvoltage Delay: ##s Thetimethatthe
generator voltage must
be in an over voltage
condition before a fault is
indicated