TP-6109 6/03
29Section 4 TroubleshootingTP-6109 6/03
Section or
Publication
Reference*
Recommended ActionsProbable Causes
Trouble Symptoms
Section or
Publication
Reference*
Recommended ActionsProbable Causes
Excessive or
abnormal noise
High fuel
consumption
Low oil
pressure
Overheats
Lacks power
Stops
suddenly
No or low
output voltage
Starts hard
Cranks but
does not start
Does not
crank
Lube System
x x x Oil level low Restore the oil level. Inspect the generator set for oil leaks. Eng. O/M
x Low oil pressure shutdown Check the oil level. Eng. O/M
x x x x
Crankcase oil type incorrect for
ambient temperature
Change the oil. Use oil with a viscosity suitable for the operating
climate.
Eng. O/M
* Sec./Section—numbered section of this manual; ATS—Automatic Transfer Switch; Eng.—Engine; Gen.—Generator Set; I/M—Installation Manual; O/M—Operation Manual; S/M—Service Manual;
S/S—Spec Sheet; W/D—Wiring Diagram
[ Have an authorized service distributor/dealer perform this service.

Other manuals for Kohler 40EFOZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 40EFOZ and is the answer not in the manual?

Kohler 40EFOZ Specifications

General IconGeneral
BrandKohler
Model40EFOZ
CategoryMarine Equipment
LanguageEnglish

Related product manuals