EasyManua.ls Logo

Kohler 50EOZ User Manual

Kohler 50EOZ
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Marine Generator Sets
TP-6109 6/03c
Operation
Models:
33EFOZ/40EOZ
40EFOZ/50EOZ
55EFOZ/65EOZ
70EFOZ/80EOZ
80EFOZ/99EOZ
100EFOZ/125EOZ
125EFOZ/150EOZ

Other manuals for Kohler 50EOZ

Questions and Answers:

Kohler 50EOZ Specifications

General IconGeneral
Model50EOZ
Power Output50 kW
Cooling SystemHeat exchanger
AC Voltage120/240V
Hertz60 Hz
Fuel TypeDiesel
Starting TypeElectric
Engine TypeDiesel
PhaseSingle or Three-phase

Summary

Introduction

Service Assistance

China

Regional contact information for Kohler Power Systems in China.

Africa, Europe, Middle East

Regional contact information for Kohler Power Systems in Africa, Europe, and Middle East.

Asia Pacific

Regional contact information for Kohler Power Systems in the Asia Pacific region.

Japan, Korea

Regional contact information for Kohler Power Systems in Japan and Korea.

Latin America

Regional contact information for Kohler Power Systems in Latin America.

Maintenance and Service Parts and Related Literature

Maintenance and Service Parts

Identifies maintenance and service parts for the generator set.

Related Literature

Identifies related literature available for the generator sets.

Section 1 Specifications

1.1 Introduction

Provides information on generator set and engine specifications.

1.2 Specifications

Details the alternator, excitation system, and voltage regulator.

1.3 Service Views

Illustrates and labels key components of the generator set.

1.4 Remote Annunciator Kit

Describes a kit for monitoring the generator set from a remote location.

1.5 Safeguard Breaker

Senses output current and shuts off AC voltage regulator on overload.

1.6 Line Circuit Breaker

Interrupts generator output on overload or short circuit.

1.7 Run Relay Kit

Includes contacts that energize during generator operation to control devices.

Section 2 Operation

2.1 Prestart Checklist

Lists checks and inspections to perform before or at each startup.

2.2 Marine Inspection

Recommends vessel inspection, especially the exhaust system, by Coast Guard Auxiliary.

2.3 Angular Operation

Details angular operation limits for units covered in the manual.

2.4 Operation in European Union Member Countries

Addresses specific regulations for operation in EU countries regarding noise emissions.

2.5 Exercising the Generator Set

Procedures for operating the generator set under load weekly for one hour.

2.6 Decision-Maker™ 3+, 16-Light Microprocessor Controller Operation

Explains the operation of the Decision-Maker 3+ controller and its modes.

2.6.1 Controls and Indicators

Describes the controls and indicators on the controller.

2.6.2 Fuses and Terminal Strips

Details fuses and terminal strips on the controller circuit board.

2.6.3 Auxiliary Fault Lamp Conditions

Defines possible auxiliary fault lamp conditions and their causes.

2.6.4 Starting the Generator Set

Provides procedures for starting the generator set locally or automatically.

2.6.5 Stopping the Generator Set

Outlines procedures for normal and emergency stopping of the generator set.

2.6.6 Prime Power Mode Operation

Explains how to enable, disable, start, and stop in prime power mode.

2.6.7 Fault Shutdowns

Lists fault conditions that cause automatic shutdown and restart requirements.

2.6.8 Controller Resetting Procedure (Following Fault Shutdown)

Details the procedure to restart the generator after a fault shutdown.

2.6.9 Resetting the Emergency Stop Switch

Outlines the procedure to restart the generator after an emergency stop.

2.7 Expanded Decision-Maker™ 1 Controller Operation

Explains the controls and functions of the expanded controller.

2.7.1 Controls and Indicators

Describes the controls and indicators located on the expanded controller.

2.7.2 Starting the Generator Set

Procedures for starting the generator set locally or automatically.

2.7.3 Stopping the Generator Set

Outlines the procedure for normal stopping of the generator set.

2.7.4 Fault Shutdowns

Lists fault conditions that cause automatic shutdown and restart requirements.

2.8 Standard Decision-Maker™ 1 Controller Operation

Explains the controls and functions of the standard controller.

2.8.1 Controls and Indicators

Describes the controls and indicators located on the standard controller.

2.8.2 Starting the Generator Set

Procedures for starting the generator set locally or automatically.

2.8.3 Stopping the Generator Set

Outlines the procedure for normal stopping of the generator set.

2.8.4 Fault Shutdowns

Lists fault conditions that cause automatic shutdown and restart requirements.

2.8.5 Controller Resetting Procedure (Following Fault Shutdown)

Details the procedure to restart the generator after a fault shutdown.

Section 3 Scheduled Maintenance

3.1 General Maintenance

Provides general maintenance safety precautions and guidelines.

3.2 Generator Set Service Schedule

Lists recommended maintenance intervals for cooling, exhaust, engine, and generator systems.

3.3 Cooling System

Covers checking coolant levels and system warnings.

3.3.1 Siphon Break

Details the procedure for inspecting the siphon break.

3.3.2 Impeller Inspection and Replacement Procedure

Outlines the steps for inspecting and replacing the seawater pump impeller.

3.4 Exhaust System

Details exhaust system inspection points and carbon monoxide warnings.

3.5 Storage Procedure

Provides procedures for storing the generator set for extended periods.

3.5.1 Lubricating System

Details preparing the lubricating system for storage.

3.5.2 Cooling System

Details preparing the cooling system for storage.

3.5.3 Fuel System

Details preparing the fuel system for storage.

3.5.4 Exterior

Details preparing the exterior for storage.

3.5.5 Battery

Details battery storage procedures.

Section 4 Troubleshooting