TP-5594 5/95 Specifications 1-1
Section 1. Specifications
General Specifications
7 kW (60Hz) 10 kW (60Hz)
Dimensions L x W x H in. (mm):
Remote Radiator (Single Phase) 30.49 x 18.43 x 25.09 35.37 x 20.22 x 25.60. . .. . .. . .. . .. . .. . .. . . .. .
(774 x 468 x 637) (898 x 514 x 650)
Inline Radiator (Single Phase/Suction Fan) 34.68 x 18.68 x 25.09 40.29 x 20.72 x 25.60. . .. . .. . .. . . .. .
(881 x 475 x 637) (1023 x 526 x 650)
Inline Radiator (Three Phase/Suction Fan) 35.68 x 18.68 x 25.09 41.29 x 20.72 x 25.60. . .. . .. . .. . . .. .
(906 x 475 x 637) (1049 x 526 x 650)
Inline Radiator (Single Phase/Pusher Fan) 35.82 x 21.18 x 26.56 40.99 x 21.18 x 27.68. . .. . .. . .. . . .. . .
(910 x 538 x 675) (1041 x 538 x 703)
Inline Radiator (Three Phase/Pusher Fan) 36.82 x 21.18 x 26.56 41.99 x 21.18 x 27.68. . .. . .. . .. . . .. . .
(935 x 538 x 675) (1067 x 538 x 703)
Weight—dry, lbs. (kg):
Remote Radiator (Single Phase) 472 (214) 576 (261). . .. . .. . .. . .. . .. . .. . .. . . . . . . . . . . . . . . . . . .
Inline Radiator (Single Phase/Suction Fan) 482 (219) 586 (266). . .. . .. . .. . .. . . . . . . . . . . . . . . . . . .
Inline Radiator (Three Phase/Suction Fan) 496 (225) 606 (275). . .. . .. . .. . .. . . . . . . . . . . . . . . . . . .
Inline Radiator (Single Phase/Pusher Fan) 482 (219) 586 (266). . .. . .. . .. . .. . .. . . .. . .. . .. . .. . ..
Inline Radiator (Three Phase/Pusher Fan) 496 (225) 606 (275). . . . . . . . . . . . . . . . . .. . .. . .. . .. . .. .
Air Requirements (Suction Fan) CFM (M
3
/min):
Combustion. 25 (0.71) 36 (1.02). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. . .. . .. . .. . ..
Cooling 1050 (29.7) 1300 (36.8). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . .. . .. . .. . .. .
Air Requirements (Pusher Fan) CFM (M
3
/min):
Combustion 25 (0.71) 36 (1.02). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .
Cooling 1000 (28.3) 1800 (51.0). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . .. . .. . .. . .. .
Fuel Inlet Size in. (mm) 5/16 (8) 5/16 (8). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .
Fuel Return Size in. (mm) 3/16 (5) 3/16 (5). . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . .. . .. . .. . .. . .. .
Fuel Consumption gph (Lph):
Model: 25% Load 50% Load 75% Load 100% Load
7 kW 0.34 (1.3) 0.44 (1.7) 0.57 (2.2) 0.79 (3.0)
10 kW 0.46 (1.7) 0.60 (2.3) 0.80 (3.0) 1.07 (4.0)
DERATION: All unitsarerated 1.0 powerfactor. Thekilowatts ofthe generatorset willdecrease 3.5%for each1,000
feet (305 meters) above 500 feet (152 meters) above sea level and 1% for each 10_F (5.5_C) above 85_F (30_C).