TP-5594 5/954-6 Troubleshooting
Generator
No AC output AC circuit breaker(s) in OFF Reset to ON position
position
No DC power to controller Check battery connections
Fuse blown Replace fuse
AC circuit breaker tripping due Reduce load (see Wattage
to overload on generator set Requirements)
Short circuit in vehicle circuit Resetif it trips repeatedly, stop
causing breaker to trip set and contact authorized service
dealer/distributor
General malfunction such as faulty Contact authorized service dealer/
component or other internal fault distributor for repairs
Low output Engine speed too low Contact authorized service dealer/
or excessive distributor for repairs
drop in
voltage Generator overloaded Reduce load
Engine in If routine services are performed
poor condition and condition persists, see
authorized service dealer/distributor
Problem Possible Cause Corrective Action