7 — DIAGNOSTICS AND TROUBLESHOOTING
pg. 241
Return to TOC  Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4.5 – April 2022
Table 24  Fault Code Troubleshooting Chart, cont’d
FLASH 
CODE
FAULT NAME  
(Curtis Integrated Toolkit™)
POSSIBLE CAUSES SET/CLEAR CONDITIONS FAULT ACTIONS 
12-13
0xCD
PWM Input 28 Out of Range
PWM_Input_28_Out_of_Range
0x210C
Fault Type(s): 
1 = The input is disconnected.
2 =  The measured input 
frequency is below the 
(PWM_Input_28_Low_
Frequency) – (PWM_
Input_28_Frequency_
Fault_Tolerance).
3 = The measured input 
frequency is above the (PWM_
Input_28_High_Frequency) + 
(PWM_Input_28_Frequency_
Fault_Tolerance).
4 =  The measured duty cycle 
is below set limits, (PWM_
Input_28_Low_Duty_Cycle) 
– (PWM_Input_28_Duty_
Cycle_Fault_Tolerance).
5 =  The measured duty cycle 
is above set limits, (PWM_
Input_28_High_Duty_Cycle) 
+ (PWM_Input_28_Duty_
Cycle_Fault_Tolerance).
1. This fault diagnostic execution 
cycles every 4msec. The input 
is considered disconnected if no 
PWM signal occurs for 16msec or 
the measurements are not updated 
every 16msec.
2. Mistuned parameters.
3. Faulty wiring.
Set: The input frequency and/or 
duty-cycle on Input 28 exceeds 
the congured limits set by 
PWM_Input_28_x_Duty_Cycle  
and PWM_Input_28_x_ 
Frequency, where x = {Low, 
High}.
Clear: Reset Controller.
Fault Action:
None, unless a fault action
is programmed in VCL.
Dual Drive
Same, both motors
13-1
0xD1
Lift Input Fault 
Lift_Input 
0x2104 
Fault Type(s): 1
The associated fault diagnostic with 
the assigned lift-input source triggers 
this fault. 
For example: 
If the Lift_Input_Source is an analog 
input, then any faults detected by the 
respective Input fault diagnostics are 
cascaded and reported within this 
fault code.
Note: An analog input fault 
diagnostics may be out of range 
when set as a voltage input or 
may include potentiometer faults if 
congured as a 2/3-wire pot.
Set: Faults from the respective/ 
assigned “Lift_Input_Source” 
are cascaded and reported.
Clear: Resolve any input 
assignment conict, or out of- 
range faults, then  
Reset Controller. 
ShutdownLift 
Dual Drive
Same, both motors
13-2
0xD2
Phase PWM Mismatch
Phase_PWM_Mismatch
0x2101
Fault Type(s): 
0 = U phase.
1 = V phase.
2 = W phase.
Internal to Controller
Motor Phase PWM.
Set: The difference between 
the commanded phase PWM 
duty cycle and the measured is 
greater than allowed.
Clear: Reset Controller. 
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Dual Drive
Same, both motors