5 — SYSTEM MONITOR MENU
pg. 151
Return to TOC Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4.5 – April 2022
SYSTEM MONITOR / INPUTS MENU: SWITCH STATUS
e On/O (1/0) indicates the state of the binary input. e same value is encoded bitwise in the variable Switches
(variable 0x3321) which contains the state of all 32 Switches as applicable to the controller. For the variable Switches,
Switch_1 corresponds to bit position 0 (LSB), and Switch_32 corresponds to bit position 31 (MSB).
VARIABLE DISPLAY RANGE DESCRIPTION
1
Switch 1
Switch_1
0x3324 0x00
On/Off
On/Off
Switch 1 On or Off (pin 16).
Note: Typically used as the 3-wire throttle Pot Wiper input.
Switch 2
Switch_2
0x3325 0x00
On/Off
On/Off
Switch 2 On or Off (pin 8).
As a digital (switch) input, internally pull up.
On is pulled to I/O Ground, Off is an open.
Note: Typically used as the Motor Temp input.
Switch 3
Switch_3
0x3326 0x00
On/Off
On/Off
Switch 3 On or Off (pin 31).
Note: Typically used as the Encoder A input; therefore will cycle Off/On.
Switch 4
Switch_4
0x3327 0x00
On/Off
On/Off
Switch 4 On or Off (pin 32).
Note: Typically used as the Encoder B input; therefore will cycle Off/On.
Switch 5
Switch_5
0x3328 0x00
On/Off
On/Off
Switch 5 On or Off (pin 9).
Note: Typically used as the Interlock input.
Switch 6
Switch_6
0x3329 0x00
On/Off
On/Off
Switch 6 On or Off (pin 15).
Note: Typically used as the 3-wire throttle Pot Hi input.
Switch 7
Switch_7
0x332A 0x00
On/Off
On/Off
Switch 7 On or Off (pin 22).
Note: Typically used as the Forward input.
Switch 8
Switch_8
0x332B 0x00
On/Off
On/Off
Switch 8 On or Off (pin 33).
Note: Typically used as the Reverse input.
Switch 9
Switch_9
0x332C 0x00
On/Off
On/Off
Switch 9 On or Off (pin 24).
Note: Typically used as the N.O. Emergency Reverse input.
Switch 10
Switch_10
0x332D 0x00
On/Off
On/Off
Switch 10 On or Off (pin 10).
Note: Typically used as the Lift input.
Switch 11
Switch_11
0x332E 0x00
On/Off
On/Off
Switch 11 On or Off (pin 11).
Note: Typically used as the Lower input.
Switch 12
Switch_12
0x332F 0x00
On/Off
On/Off
Switch 12 On or Off (pin 12).
Note: Typically used as the optional fork’s Travel Limit input.
Switch 13
Switch_13
0x3330 0x00
On/Off
On/Off
Switch 13 On or Off (pin 14).
Note: Typically used as the N.C. Emergency Reverse input.
Switch 14
Switch_14
0x3331 0x00
On/Off
On/Off
Switch 14 On or Off (pin 25).
Note: The +12V supply (pin 25), if not enabled, can be congured as a
switch input.
Switch 18
Switch_18
0x333D 0x00
On/Off
On/Off
Switch 18 On or Off (pin 17).
Note: Typically used as the 2 or 3-wire Pot Wiper input.
1
Pin number is on a 35-pin controller basis. For 23-pin controllers, use the variable name (see Fig. 12).