EasyManuals Logo

Kohler K482 User Manual

Kohler K482
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
If
contact points are badly worn
or
pitted, they must be replaced.
Do not replace only one con
-
tact
--
replace both the fixed contact and contact on breaker arm. Replace as follows:
1. Remove breaker spring contact screw then breaker arm lock and washer.
2.
Lift breaker
arm
off pivot
-
-
discard arm.
3.
Remove the two breaker plate contact screws then remove and discard the fixed contact
plate.
4.
Position and secure new contact plate and breaker arm then adjust breaker point gap per
instructions stated in the foregoing.
5.
Replace old cam wick with new wick
--
lubricate with Rycon grease.