88 TP-6694 2/25
50-150 kW Models
See Figure 35 and Figure 36.
Natural Gas Connections
• Disconnect lead 65 from lead N5.
• Disconnect leads 70G, 73B, and N8 from fuel solenoid valve FV2 (LPG vapor).
• Connect leads 70E, 73A, and 73B to fuel solenoid valve FV1 (NG).
LPG Vapor Connections
• Disconnect leads 70E, 73A, and 73B from fuel solenoid valve FV1 (NG).
• Connect leads 70G, 73B, and N8 to fuel solenoid valve FV2 (LPG vapor).
• Connect lead 65 to lead N5 (ground).
LPG Liquid Withdrawal Connections
• Connect leads 70G, 73B, and N8 to fuel solenoid valve FV2 (LPG vapor).
• Connect lead 65 to lead N5 (ground).
Dual Fuel Automatic Changeover Connections
Dual-fuel automatic changeover systems change fuels automatically. No changes in the fuel connections are required to change
from NG to LPG or vice-versa. See Figure 36 for connections.