TP-6881 7/1532 Section 3 Controller
SiteTech Group Parameter Units
Adjustment
Range *
Default
Setting
Notes [
Identity Vendor Read Only Kohler
Company
Identity Product Read Only RDC2
Identity Firmware Version Read Only N/A
Engine Metering Engine Speed R/min Read Only N/A
Engine Metering Engine Target Speed R/min Read Only N/A
Engine Metering Engine Oil Pressure kPa Read Only N/A
Engine Metering Engine Coolant Temperature _C Read Only N/A
Engine Metering Battery Voltage V Read Only N/A
Engine Metering Lube Oil Temperature _C Read Only N/A
Engine Metering Genset Controller Temperature _C Read Only N/A
Engine Metering Engine Low Oil Pressure
Switch
Read Only N/A
Engine Metering Engine Compartment
Temperature
_C Read Only N/A
Engine Speed Governor Engine Speed Adjustment 0--99
See Section 3.3.2.
50
Engine Speed Governor Engine Speed Gain Adjustment No effect. 50 N/A
Generator Metering Generator Rotation Actual Read Only N/A
Generator Metering Generator Current Lead/Lag L1 Read Only N/A
Generator Metering Generator Current Lead/Lag L2 Read Only N/A
Generator Metering Generator Current Lead/Lag L3 Read Only N/A
Generator Metering Generator Current Total
Lead/Lag
Read Only N/A
Generator Metering Generator Power Factor L1 Read Only N/A
Generator Metering Generator Power Factor L2 Read Only N/A
Generator Metering Generator Power Factor L3 Read Only N/A
Generator Metering Generator Total Power Factor Read Only N/A
Generator Metering Generator Apparent Power L1 VA Read Only N/A
Generator Metering Generator Apparent Power L2 VA Read Only N/A
Generator Metering Generator Apparent Power L3 VA Read Only N/A
Generator Metering Generator Total Apparent
Power
VA Read Only N/A
Generator Metering Generator Reactive Power L1 VAR Read Only N/A
Generator Metering Generator Reactive Power L2 VAR Read Only N/A
Generator Metering Generator Reactive Power L3 VAR Read Only N/A
Generator Metering Generator Total Reactive Power VAR Read Only N/A
Generator Metering Generator True Power L1 W Read Only N/A
Generator Metering Generator True Power L2 W Read Only N/A
Generator Metering Generator True Power L3 W Read Only N/A
Generator Metering Generator True Total Power W Read Only N/A
Generator Metering Generator True Percent Of
Rated Power
% Read Only N/A
Generator Metering Generator Voltage L1-L2 V Read Only N/A
Generator Metering Generator Voltage L2-L3 V Read Only N/A
Generator Metering Generator Voltage L3-L1 V Read Only N/A
* Read Only = Not adjustable
w Load management device (LCM, load shed kit, or RXT w ith c ombined interface/ load management board).
[ Notes indicate applicability to genset or accessories. N/A = Not applicable to the models covered in this manual.
] See TT-1584 for more information about digital inputs and outputs.
Grayed rows are visible in SiteTech but do not apply to all models.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Power Systems 8RESV and is the answer not in the manual?

Kohler Power Systems 8RESV Specifications

General IconGeneral
BrandKohler
ModelPower Systems 8RESV
CategoryPortable Generator
LanguageEnglish

Related product manuals