The item nos. below refer to the system diagram on the opposite page.
Item no.
Designation Description
1 analog cable shielded, twisted pairs, 3x2x0.25mm²
2 shield terminal clamps various sizes, manuf. Weidmüller, type KLBÜ
3 mains adapter 24VDC/xA auxiliary voltage supply
4 1EF06 mains filter, manuf. Seidel, single-phase
5 mains cable shielded, 4x1.5 mm²
6 3EFxx mains filter, manuf. Seidel, for various currents
7 digifas™ 72xx servo amplifier, manuf. Seidel, various versions
8 ROD/SSI cable shielded, twisted pairs, 4x2x0.25mm²
9 resolver cable manuf. Seidel, ready-made, can be trailed
10 EMC-RES-connector component of resolver cable manuf. by Seidel
11 woven tape manuf. Seidel, ready-made
12 motor-/brake cable manuf. Seidel, shielded, can be trailed, with or
without integral brake cable, in case of shielded
motor cable length £ 25m : 1.5mm²
length 25m to 100m: 1mm² with motor choke box
13 EMC-PGxx PG screwed gland, built into the terminal box
of motor series 6SM45,56
EMC-Power connector EMC power conn. for motors 6SM27/37/47/57/77
14 6SMxx synchronous servo-motor, various frame sizes
15 ring core ferrite ring
x = various value
Make a selection from our price list. Configure your own tailor-made servo system from
our individual components.
Our applications department is always available to deal with your queries.
The components listed below do not have any decisive effect on the conformance of single-axis
systems to the standards. However, for multi-axis systems item F may need to be shielded,
depending on the length.
A — 7 x 0.5mm
2
, single cores
B — PC cable, manuf. Seidel
C — line driver (booster)
D — earth lead, 1.5 ... 16mm
2
F — length more than 20cm : shielded cable, 7x1.5mm
2
length up to 20cm : 5 single cores, 1.5mm
2
Chapter VI Appendix Page VI - 3
digifas
®
7200 series 03.98
Only under the condition that the system components listed below are used and that the
commissioning instructions in this documentation (Chapter II.1 ff) are followed, can we
guarantee the conformance of the servo amplifier with the following standards for
industrial areas:
— EC EMC Directive 89/336/EEC
— EC Low Voltage Directive 73/23/EEC
If there is any deviation from these requirements you must provide your own
measurements to demonstrate conformance to the standards.