7) Fast spd (Fast Speed): You can select the speed of the screwdriver during the FAST SPEED. It can be
set between max speed and the Final Speed (see point 8).
This function is available only if the Fast Speed Time is ON.
8) Final Spd (Final Speed): You can select any speed value of the screwdriver between nominal
(maximum speed given in the catalogue) and the minimum speed of every single screwdriver (see table with
technical data).
9) Runtime: You can set the time of a tightening, from OFF to 20.0 sec. When the pre-set time has been
reached, it results in a torque signal.
The couple reached during this time results in a signal of Correct screw. If the correct screw signal is not
required, set the Minimum time up to a value of 'Minimum Time -0.1sec'.
ATTENTION: Max Time must be set at 20.0 sec.
10) Min time - Minimum Time: You can select the minimum time of screwing from 0.1 sec to 'Max
time - 0.1s'. To disable the function press until you get to OFF (Min time = 0).
Torque reached below the minimum time won’t activate the torque signal and will result in an error
signal. “Below minimum time” will be displayed on the status bar and the red led will light up. You will
hear two beep sounds, too.
11) Max time - Maximum time: You can select the maximum time of screwing. You can set from 'Min
time + 0,1s' to 20.0 sec.
You also can set the Maximum time to OFF by pressing the button when you have reached the value of
20.0s. In this case the screwdriver turns without any time limit.
ATTENTION: If torque isn’t reached by the maximum time, the screwdriver will stop. “Over maximum
time” will be displayed on the status bar and the red led will light up. You will hear two beep sounds, too.
12) Pre-Rev.: pre-reverse. You can unscrew before tightening. This time can be set from OFF to 20.0 sec.
N.B. The speed and torque will be the same as those for the Auto Reverse.