40 Troubleshooting SEN04120-03
PC130-8
17
Failure code [CA488] Chg air temp high torque derate 1
User code Failure code
Trouble
Charge air temperature high torque derate
(Engine controller system)
E11 CA488
Contents of
trouble
Temperature signal of boost pressure/temperature sensor exceeded control upper temperature
limit.
Action of
controller
Limits output and continues operation.
Problem that
appears on
machine
Engine output lowers.
Related
information
Boost temperature can be checked with monitoring function. (Code: 18500 Boost temperature)
Method of reproducing failure code: Start engine.
Possible causes
and standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
1
Lowering of cooling perfor-
mance of aftercooler
Cooling performance of aftercooler may be low. Check following
points directly.
Looseness and breakage of fan belt.
Insufficiency of cooling air
Clogging of aftercooler fins
2
Abnormal rise of turbo-
charger outlet temperature
Outlet temperature of turbocharger may be abnormally high.
Check related parts directly.
3 Defective engine controller
If causes 1 – 2 are not detected, engine controller may be defec-
tive. (Since trouble is in system, troubleshooting cannot be carried
out.)

Table of Contents