MACHINE OPERATIONS AND CONTROLS OPERATION
3-182
3. Lower the bucket horizontally until the bottom touches the
ground.
4. Set lock lever (3) in the LOCK position (L).
5. Check the engine cooling water temperature and engine oil
pressure with the machine monitor.
q If the coolant temperature gauge is in the red range,
allow it to cool until the indicator enters the green
range, then stop the engine. For details of the inspec-
tion and action to take, see “TROUBLES AND
ACTIONS (3-201)“.
q If the engine oil pressure monitor lights up, stop the
engine immediately. For details of the inspection and
action to take, see “TROUBLES AND ACTIONS (3-
201)“.
6. Stop the engine. For details on the procedure for stopping
the engine, see “STOPPING THE ENGINE (3-153)“.
MACHINE INSPECTION AFTER DAILY WORK 3
1. Walk around the machine and check the work equipment, machine exterior, and undercarriage, also check for
any leakage of oil or coolant. If any problems are found, repair them.
2. Fill the fuel tank.
3. Check the engine compartment for paper and debris. Clean out any paper and debris to avoid a fire hazard.
4. Remove any mud affixed to the undercarriage.

Table of Contents

Other manuals for Komatsu PC350LC-8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu PC350LC-8 and is the answer not in the manual?

Komatsu PC350LC-8 Specifications

General IconGeneral
BrandKomatsu
ModelPC350LC-8
CategoryExcavators
LanguageEnglish

Related product manuals