KONE ReSolve 200
Installation Instruction
9 (258) AM-10.65.001
(D) 2013-04-17
© 2009 KONE Corporation
All rights reserved.
Special things about the method
This work must not disturb the normal operations or elevator users in the building. The
working times must be agreed with the building owner carefully.
If the elevator is a member of an elevator group the operation of the existing group control
must be guaranteed during the works.
When the connections between the old group and/or the other elevators and this elevator are
disconnected, agree with the customer about the procedure and timing. Follow local rules.
In case the elevator is connected to external alarm systems (KONEXION), the forwarding of
alarms must be inhibited for the installation time.
Temporary connections for landing locks and service drive limit switch are needed.
To ensure public safety and your own safety, this method uses a special tool to connect the
old and new safety circuits in series by overconnecting the landing door locks.
Installation of shaft light can be done first if the elevator has a car inspection box.
Related documents
For more information, see:
AM-01.03.001 Take 5 - Electrical safety when working on elevators
AM-01.03.010 Safe working in elevator shaft and machine room areas
AM-01.01.085 Planning guide and general instructions for low-rise elevator dismantling
AM-12.20.005 KONE signalization system (KSS) installation
AS-11.65.004 Replacement of V3F10 and V3F10CL drive module (V
3
F inverter unit)
AS-10.60.001 Site reference guide for KONE MMS Resolve 10 and 20 electrification
AS-10.65.006 Diagnostic guide for KONE ReSolve 200 commissioning
AS-10.65.007 Fault finding instruction for KONE ReSolve 200
AS-12.02.001 Instruction for handling electrostatic-discharge-sensitive-devices on site
UM-10.65.001 User manual for KCE removable user interface
UM-10.65.002 KONE Maintenance Interface, European Norm Version
1374567 KCE parameter list
958174D01 KCE fault code list
773556D01 Door inverter instructions
873805 V3F10/K7/K1000 Yaskawa drive parameter list
878327 V3F10 fault codes
834948 Tool for calculating V3F open loop parameters
TC000034 KCE Electrification, Core learning guide
TC000035 KONE ReSolve 200 Electrification Core Training Guide
TC000036 V3F10 Drive Core Learning Guide
TC000037 KCE Electrification, Special Technology
TC000123 KCE KONE Maintenance Interface, Core learning guide