EasyManua.ls Logo

Kongskilde MULTIAIR 2000 - Maintenance; Lubrication; Transmission and Belt Tension; Cleaning

Kongskilde MULTIAIR 2000
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Maintenance
In case of abnormal noise or vibra-
tions, stop the blower and repair the
defect before restarting the blower.
Lubrication
The blower bearings are lubricated
from the factory and require no
further maintenance.
Transmission
Too taut or too slack ribbed belts
reducetheefciencyandlifeofthe
belt drive.
The best way of checking the ten-
sion of the ribbed belt is using the
Optibelt belt tension tester (addi-
tional equipment, see page 16).
After a running-in period of 0.5 to
4 hours of operation at full load
the ribbed belt should be checked
initially.
Tension the belt if required. The
extension taking place during the
running-in hours has now been
corrected.
We recommend regular control of
the belt tension, e.g. at intervals of
six months/2000 hours. Retension
when required.
To mount the ribbed belt reduce the
centre-to-centre distance so that
the belt may be mounted loosely.
Belts which have been forcibly
mounted or pulled over the belt pul-
ley will always be damaged.
Align the pulleys so that the
groovesareush.
Abnormal heat generation, vibra-
tions or an excessive sound level
will normally be caused by foreign
matter in the grooves, incorrect belt
tension or loose pulleys.
Cleaning
Always ensure unimpeded ac-
cess of cooling air to and from the
blower.
Tension control by means of Optibelt belt tension tester (additional
equipment)
Multiair New belts Control/tensioning
2100 (50/60 Hz) min 500N min 450N
max 600N max 500N
2150 (50/60 Hz) min 600N min 500N
max 700N max 600N
2200 (50/60 Hz) min 700N min 550N
max 800N max 600N
Only 2200 (60 Hz)
With motor/blower min 800N min 600N
pulley: 218/158 max 900N max 700N
2250 (50/60 Hz) min 850N min 650N
max 950N max 700N