126 Part Number STH063 9/17
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Machine
Freeze Time Harvest
Time
11.0-11.9 11.6-12.5 13.4-14.4
1.0-2.5
11.2-12.0 11.5-12.4 13.5-14.6
11.4-12.3 13.0-14.0 13.6-14.7
11.6-12.5 13.3-14.3 13.9-14.9
11.7-12.6 13.5-14.6 14.1-15.2
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
835 800 700
825 805 695
810 720 690
800 705 680
790 695 670
Based on average ice slab weight of 7.25 – 7.75 lb (3.3 – 3.5 kg)
Water regulating valve set to maintain 300 PSI discharge pressure.
Condenser Water usage per 100 lbs ice = 131 gal (45 kg = 496 L)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Around Ice
Machine
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
290-305 64-36 150-165 100-125
290-305 64-36 150-165 100-125
290-310 68-37 155-175 100-125
295-335 72-39 160-180 110-125
305-335 73-41 160-180 110-130
310-345 74-44 165-185 115-130
Suction pressure drops gradually throughout the freeze cycle