Setting the Machine Number:
When using a single VS-88HDxl unit, set the unit to Machine # 1.
When connecting more than one VS-88HDxl unit set a unique Machine # for each unit. The units do not have to be
numbered sequentially. The master unit must be set to Machine #1.
To set the machine # for each unit, set the DIP switches according to the relevant row in the following table:
Machine #
DIP-SWITCH
1
2
3
4
1 (Single or master
unit)
OFF or ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Note: After changing the machine #, the unit must be reset by turning it OFF and ON.
Setting the RS-485 Line Termination:
The RS-485 TERM DIP switch on the first and last units on the RS-485 line must be set to
ON (terminated) and all other units must be set to OFF (not terminated).
Note: The master unit may be located at any part of the line.
Setting the Genlock Video Signals:
To set the Genlock video signals according to timing of the Genlock reference input:
1. Connect the Genlock cable.
2. Press and hold, for 3 seconds, the relevant IN SELECT button according to the table:
IN SELECT Button
Genlock Setting
1
1080i/p @60Hz
2
1080i/p @50Hz
3
720p @60Hz
4
PAL @50Hz
5
NTSC @60Hz
The Genlock setting changes and the new setting is displayed in the INPUT display.
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/VS-88HDxl.
Using third-party cables may cause damage!
Step 5: Connect power
Connect the power cord to VS-88HDxl and plug it into the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
There are no operator serviceable parts inside the unit.
Warning:
Use only the power cord that is supplied with the unit.
Disconnect the power and unplug the unit from the wall before installing.
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.