Kramer Electronics Ltd.
VW-9 Protocol 3000
41
Protocol 3000
Kramer devices can be operated using Kramer Protocol 3000 commands sent via serial or
Ethernet ports.
Understanding Protocol 3000
Protocol 3000 commands are a sequence of ASCII letters, structured according to the
following.
Command format:
Prefi
x
Command Name
Constant (Space)
Parameter(s)
Suffix
#
Command
Parameter
<CR>
Feedback format:
Prefix
Device ID
Constant
Command Name
Parameter(s)
Suffix
~
nn
@
Command
Parameter
<CR><LF>
Command parameters Multiple parameters must be separated by a comma (,). In
addition, multiple parameters can be grouped as a single parameter using brackets ([
and ]).
Command chain separator character Multiple commands can be chained in the
same string. Each command is delimited by a pipe character (|).
Parameters attributes Parameters may contain multiple attributes. Attributes are
indicated with pointy brackets (<…>) and must be separated by a period (.).
The command framing varies according to how you interface with VW-9. The following figure
displays how the # command is framed using terminal communication software (such as
Hercules):