6
Description
Electrical connection
The machine is suplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket with
a
30 mA residual current operated device. The socket must be
protected with a 16 A slow fuse on the mains inside.
KRÄNZLE 105 - 230 Volt 50 Hz
When using an extension cable, this must have an earthed lead
which is properly connected to the socket. The conductors in the
extension cable must have a minimum cross section of 1,5 mm
2
.
Plug connections must be of a spray proof design, and may not
be located an a wet floor.
(With extension cables of more than 10 m the conductor must
have cross section of at least 2,5 mm
2
.)
CAUTION !
The use of extention cables which are too long may lead to malfunctions and
start-up difficulty.
When using a cable drum, always keep the cable wound as far as possible.