EasyManuals Logo

Kranzle K125 User Manual

Kranzle K125
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
Electrical connection
The machine is supplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket
with a 30mA residual current operated device. The socket must
be protected with a 16A delay action fuse on the mains side.
KRÄNZLE 115, 125, and 135 - 230 Volt 50 Hz
KRÄNZLE 155 - 400 Volt 50 Hz (phase-sequence not
significant)
When using an extension cable, this must have an earthed lead
which is properly connected to the socket. The conductors in the
extension cable must have a minimum cross section of 1.5 mm².
Plug connections must be of a spray-proof design, and may not
be located on a wet floor.
(with extension cables of more than 10 m - 2.5 mm
2
)
CAUTION !
The use of extension cables which are too long may lead to malfunctions
and start up difficulty.
When using a cable drum, always keep the cable wound as far as possible.
Description

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kranzle K125 and is the answer not in the manual?

Kranzle K125 Specifications

General IconGeneral
BrandKranzle
ModelK125
CategoryPressure Washer
LanguageEnglish

Related product manuals