Product Description
8/18 810.00113.0
2 Product Description
2.1 Usage in the specified manner
The oil level regulator monitors and controls the oil level in the refrigerant compressors.
Details can be found in the corresponding data sheet.
The INT280 adapters (see Chapter Accessories) serve to connect the oil level regulator to refrigerant compressors.
The necessity and possibly the selection of an adapter are determined by the design of the sight glass of the
refrigerant compressor.
Special specifications on usage in the specified manner:
The KRIWAN oil level regulators may be operated only within their specified performance limits (see Technical
specifications chapter of the respective data sheet).
Observing the installation instructions and following the maintenance and repair regulations are a prerequisite for
use in the specified manner.
Any other or further usage is deemed as usage not in the specified manner.
2.2 Reasonably foreseeable misuse
Operation in potentially explosive areas is not permitted.
Operation in flammable areas is not permitted.
Modifications to the device are not permitted.
Spare parts or accessories not supplied by the manufacturer are not permitted because they have not been
tested for the operation and they may negatively affect operational safety.
2.3 CE Declaration
The valid CE Declaration can be requested from the manufacturer.
2.4 Application limits
2.4.1 Mechanical limits
Mechanical limits according to drawing and technical data on the separate data sheet or in the description of the
accessories of this document.
2.4.2 Energy limits
Electrical: Connection specifications refer to separate data sheet.
2.4.3 Temporal limits
Until shut-down.
2.4.4 Operator limitations
3 Transport and Storage
The manufacturer assumes no liability for damages caused by misuse.
Normal mode: trained personnel
Maintenance / Repair: trained, qualified personnel
Soiling of the oil level regulator, in particular the oil connections.
Soiling can cause malfunctions.
 Transport and storage only in the original transport packaging or in a suitable individual
packaging.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KRIWAN INT280 and is the answer not in the manual?

KRIWAN INT280 Specifications

General IconGeneral
BrandKRIWAN
ModelINT280
CategoryController
LanguageEnglish

Related product manuals