3. Exploded drawings with the data needed to order spare parts
PERIODIC MAINTENANCE
OPERATION FREQUENCY
To keep the lift working at full efficiency, follow the indicated maintenance schedule. The manufacturer
will not be responsible and will not honor the warranty as a result of
non-compliance with the instructions indicated above.
NOTE
The frequency indicated refers to normal operating conditions; different frequencies will apply to
particularly server conditions.
ALL MAINTENANCE OPERATIONS MUST BE PERFORMED WITH THE LIFT STOPPING OR THE
MAIN SWITCH PLACED AT "O".
When after the machine has been installed, check:
1 That the opposite carriages arms are at the sarne leve!
2 The power unit oil leve!. Add oil up to the right leve!, if necessary
3 EVERY MONTH
10. HYDAULIC POWER UNIT
1
Check the oil leve! in the tank, using the special dipstick, which is attached to the filler cap. lf
necessary, add oil through the cap to reach the required leve!. For the type of oil, see
''TECHNICAL SPECIFICATIONS".
2
After the first 40 hours of operation, check the press oil contamination leve!. (Clean the filter and
replace the oil if there is a high contamination leve!).
HYDRAULIC CIRCUIT
Check that there are no oil leaks in the circuit between the power unit and cylinder and in the cylinder
itself. ln this case, check the condition of the gaskets and replace them, if necessary.
HYDRAULIC PUMP
Under normal operating conditions, check that there is no change in the noise in the motor and gear
pump and check that the relative bolts are properly tightened.
SAFETY SYSTEMS
1 Check the operating condition and efficiency of the safety devices .
2 Use a torque wrench to check that the post bases anchor bolts screws are properly tightened to
the ground as well as the connection bolts.
3 Clean and lubricate the carriage side runners and guides.
4 Check that all screws are tightened