SPECIAL CONDITIONS 2
15
OPTIMASS / 400
www.krohne.com10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
2.5.6 OPTIMASS 2000F / 2400C
OPTIMASS 2000F
OPTIMASS 2400C with aluminium converter housing
OPTIMASS 2400C with Stainless Steel converter housing
VE ab c...m n p...w
87...90 1 or 2
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+65 65 T6 - T1 T80
80 T5 - T1 T95
115 T4 - T1 T130
130 T3 - T1 T160
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
VE ab c...m n p...w
87...90 0
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+50 50 T6 - T1 T80
130 T3 - T1 T160
-40...+55 100 T4 - T1 T130
120 T3 - T1 T150
-40...+60 90 T4 - T1 T120
-40...+65 65 T5 - T1 T95
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
VE ab c...m n p...w
87...90 0
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+40 130 T3 - T1 T160
-40...+45 100 T4 - T1 T130
110 T3 - T1 T140
-40...+50 50 T6 - T1 T80
90 T4 - T1 T120
-40...+55 65 T5 - T1 T95
75 T4 - T1 T105
-40...+60 60 T5 - T1 T90
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C