2 SPECIAL CONDITIONS
18
OPTIMASS / 400
www.krohne.com 10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
2.5.8 OPTIMASS 6000F / 6400C +150°C
OPTIMASS 6000F
OPTIMASS 6400C with aluminium converter housing
VE ab c...i j k...m n p q r...w
71...79 0 1 or 2 0 or 1
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+55 55 T6 - T1 T80
150 T3 - T1 T190
-40...+60 145 T3 - T1 T170
-40...+65 70 T5 - T1 T95
105 T4 - T1 T130
135 T3 - T1 T175
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
Table 2-1:
VE ab c...i j k...m n p q r...w
71...79 0 0 0 or 1
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+40 40 T6 - T1 T80
-40...+45 150 T3 - T1 T190
-40...+50 145 T3 - T1 T185
-40...+55 55 T5 - T1 T95
120 T3 - T1 T160
-40...+60 90 T4 - T1 T130
-40...+65 65 T4 - T1 T105
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
Table 2-2: