EasyManua.ls Logo

KROHNE OPTIMASS 3400C - Converter VE Code I; O Overviews

KROHNE OPTIMASS 3400C
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 ELECTRICAL CONNECTIONS
34
OPTIMASS / 400
www.krohne.com 10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
3.2.3 Converter VE code I / O overviews
Non intrinsically safe I/O connections
I/O PCB Input / output functions (U
n
<32 VDC, I
n
<100 mA U
m
= 253
V)
Basic I/O Active / passive current output with HART
Status output / control input
Status output
Pulse / status output
Modular I/O Active or passive current output with HART (according to
options selected)
Active or passive pulse status output, highC or Namur
(according to options selected)
Modular carrier with 1 or 2 I/O modules Each module can have one of the three following I/O
functions:
Active or passive current output
Active or passive status / pulse output, high current or
Namur
Active or passive control input, high current or Namur
Profibus DP I/O Profibus DP, active
Fieldbus I/O Profibus PA or Foundation Fieldbus
RS485 Modbus Modbus, with or without termination