page 33
INSTALLER SECTION
table 2 - push-button key code 50570/G
P Parameter Min. MAX.
Measure
Unit
Default Notes
1 Rinse time cycle 25 45 s 35s step 1"
2 Boiler temperature setting 65 87 °C 85°C step 1/2°C
3 Tank temperature setting 50 65 °C 55°C step 1/2°C
4 Energy-saving threshold cycle 1 10 40 °C 10°C step 1/2°C
5 Energy-saving threshold cycle 2 10 40 °C 15°C step 1/2°C
6 Energy-saving threshold cycle 3 10 40 °C 20°C step 1/2°C
7 Energy-saving threshold cycle 4 10 40 °C 20°C step 1/2°C
8 Water load time-out 60 800 s 200s step 5s
9
Atmospheric pressure boiler load
time-out
100 600 s 100s step 5s
10 Energy saving enabled 0 1 1 1=enabled
11 Thermostop enabled 0 1 1 1=enabled
12 Start whit door enabled 0 1 0 1=enabled