EasyManua.ls Logo

kromo KP202E - SIGNALS AND ALARMS

kromo KP202E
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
page 42
7. SIGNALS AND ALARMS
The alarm messages are displayed, based upon their meaning.
When displaying "DETERGENT LEVEL"add detergent in the detergent tank (only with
optional"SensorforChemicalsLowLevel").
Whendisplaying"RINSE-AIDLEVEL"addrinse-aidchemicalintherinse-aidtank(onlywith
optional"SensorforChemicalsLowLevel").
Whendisplaying"DOOR OPEN"meansthattheopendoordoesnotallowthemaneuver
tried, or a wash cycle was in progress, when lifting the door.
TYPE OF ALARM CAUSE REMEDIES
B1 BOILER NOT FILLED
Open the water supply valve and verify a proper water
supplyow.ContactTechnicalService
B2 BOILER SENSOR FAILURE
Contact Technical Service
B3 BOILER NOT HEATED
Contact Technical Service
B4 FAILURE IN RINSING
Contact Technical Service
B5 BOILER OVERTEMPERATURE
Contact Technical Service
E1 WASH-TANK NOT FILLED
Open the water supply valve.
Contact Technical Service
E2 WASH-TANK SENSOR FAILURE
Contact Technical Service
E3 WASH-TANK NOT HEATED
Contact Technical Service
E5 WASH-TANK OVERTEMPERATURE
Contact Technical Service
E6 TANK DRAINING FAILURE
Checktheoverowpipe.ContactTechnicalService
E7 WASH PUMP THERMAL RELAY 1
WASH PUMP THERMAL RELAY 2
Contact Technical Service
Table. 2

Related product manuals