Terminal error messages 8
Faults of the electrics/electronics 8.1
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 81
Possible cause Remedy
FMI 11: The error cause is unknown.
The supply voltage of the
sensors could not be activ-
ated.
Note the error number and the FMI. Then contact the
dealer.
521107-
High
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause Remedy
FMI 3: There is a short circuit or an overvoltage.
The cabling is faulty.
Check the cabling for damage, refer to page73.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage, refer to page73.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521107-
Low
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause Remedy
FMI 4: There is a cable break/short circuit, general error or undervoltage.
The cabling is faulty.
Check the cabling for damage, refer to page73.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage, refer to page73.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521108-
Low
Voltage group (UB1) has failed the self-test.
Possible cause Remedy
FMI 4: There is a cable break/short circuit, general error or undervoltage.
There is a cable break or
short circuit.
Note down the error number on the FMI and contact the
service partner.
521109-
Low
Voltage group (UB2) has failed the self-test.
Possible cause Remedy
FMI 4: There is a cable break/short circuit, general error or undervoltage.
There is a cable break or
short circuit.
Note down the error number on the FMI and contact the
service partner.