Max. DC Input Power (kW) | 33 |
---|---|
Max. DC Input Voltage (V) | 1100 |
Start Voltage (V) | 200 |
MPPT Voltage Range (V) | 200-1000 |
Number of MPPT Trackers | 2 |
Rated AC Output Power (kW) | 30 |
Max. AC Apparent Power (kVA) | 33 |
Max. Output Current (A) | 47.8 |
Rated AC Voltage (V) | 400 |
AC Voltage Range (V) | 310-480 |
Rated Grid Frequency (Hz) | 50/60 |
Total Harmonic Distortion (THD) | <3% |
DC Switch | Yes |
Protection Class | IP65 |
Efficiency | 98.6% |
Altitude | 4000m |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Operating Temperature Range (°C) | -25~60 |
Protection Features | Overvoltage |
Operating Temperature | -25 to +60 |
Storage Temperature | -40°C to 70°C |
Humidity | 0-100% |
Details how to check for damage and missing accessories after opening the package.
Introduces the interface for inquiring about inverter information.
Displays recorded fault and warning alarms with timestamps.
Introduces the interface for viewing various statistical data.
Details the process of entering the setup interface and changing parameters.
Shows specific numerical values for error codes.
Introduces the section for configuring various working parameters of the inverter.
Details how to reset inverter parameters to default settings.
Lists the built-in protection devices of the inverter.
Lists the grid standards supported by the inverter.
Explains safety symbols used in the manual, indicating potential risks.
Outlines specifications for installations and usage to ensure safety and compliance.
Lists essential safety instructions for operating and handling the inverter.
Provides criteria for selecting an appropriate installation location for the inverter.
Details the process and considerations for securely mounting the inverter.
Outlines the steps for making electrical connections to the inverter.
Describes the procedure for connecting the AC output of the inverter.
Explains how to establish the external ground connection for the inverter.
Details how to connect the inverter for monitoring via Wi-Fi or GPRS.
Describes the connections for the Demand Response Enable Device (DRED) port.
Explains how to connect the photovoltaic (PV) side of the inverter.
Lists recommended OCPD ratings for protecting inverter circuits.
Explains how to connect optional meters for the inverter's export limitation function.
Provides step-by-step instructions for starting up the inverter.
Details the procedures for safely shutting down the inverter.
Provides general maintenance guidelines for the inverter.
Lists common problems and their solutions for the inverter.
Outlines the terms and conditions for product warranty and service.