EasyManua.ls Logo

KTM F8401V5 - 3.11 Disconnecting the negative cable of the 12-V battery; 3.12 Connecting the negative cable of the 12 V battery

KTM F8401V5
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WORK 3
21
Disconnect the battery charger after charging the 12-V battery.
Guideline
The charging current, charging voltage, and charging time
must not be exceeded.
Recharge the 12-V battery
regularly when the motorcy-
cle is not being used
3 months
Finishing work
Connect the negative cable of the 12 V battery. ( p. 21)
Mount the seat. ( p. 17)
3.11 Disconnecting the negative cable of the 12-V battery
Preparatory work
Remove the seat. ( p. 16)
R01414-10
Main work
Disconnect negative cable
1
of the 12-V battery.
3.12 Connecting the negative cable of the 12 V battery
T02638-10
Main work
Connect negative cable
1
of the 12 V battery.
Guideline
Screw, battery termi-
nal
M5 2.5 Nm
(1.84 lbf ft)
Contact disks
A
must be mounted under the screw
2
and
the cable lug
3
with the claws toward the battery terminal.
Finishing work
Mount the seat. ( p. 17)

Related product manuals