WORK 3
21
– Disconnect the battery charger after charging the 12-V battery.
Guideline
The charging current, charging voltage, and charging time
must not be exceeded.
Recharge the 12-V battery
regularly when the motorcy-
cle is not being used
3 months
Finishing work
– Connect the negative cable of the 12 V battery. ( p. 21)
– Mount the seat. ( p. 17)
3.11 Disconnecting the negative cable of the 12-V battery
Preparatory work
– Remove the seat. ( p. 16)
R01414-10
Main work
–
Disconnect negative cable
1
of the 12-V battery.
3.12 Connecting the negative cable of the 12 V battery
T02638-10
Main work
–
Connect negative cable
1
of the 12 V battery.
Guideline
Screw, battery termi-
nal
M5 2.5 Nm
(1.84 lbf ft)
Contact disks
A
must be mounted under the screw
2
and
the cable lug
3
with the claws toward the battery terminal.
Finishing work