ELECTRICAL SYSTEM
KX080-4, WSM
4-S35
[6] TABLE OF METER PANEL MESSAGES AND ERROR HISTORY
LIST
(1) Red Warning Lamp Lit
When needed, pressing switch 4 displays a detailed description.
No. Screen display Pressing SW4 Message in fail record Reason detected/steps to take
1–
[Meter]
Engine oil pressure error
a)Engine oil pressure low
b)Oil switch always ON
c)Short in harness
2–
[Meter]
Overheated
Engine overheated [118°C
(244°F)--automatically goes to idle]
3–
[Meter]
Charging System Error
Low alternator voltage detected
a)Alternator faulty
b)Fan belt loose/off
c)Break in harness
d)Fuse blown (10 A)
4–
[Meter]
Fuel Sensor Error
a)Connector disconnected
b)Break in harness
5
CANSys (main)
[Meter]
CAN Sys (Main)
a)Connector disconnected
b)ECU (+B) fuse blown (5 A)
c)Break or short in harness
CANSys (CRS)
[Meter]
CAN Sys (CRS)
a)Connector disconnected
b)Slow blow fuse (CRS) blown (30 A)
c)Engine ECU relay faulty
d)Break or short in harness
6–
[Meter]
Setup Data Error
Go through the model setup again. If this
doesn't fix it, it's a faulty meter.
7–
[Main ECU]
Water mixed with fuel
a) Water mixed with fuel in the fuel filter
[Reference value:80 to 130 ml
(0.07 to 0.11 lmp·qts, 0.08 to 0.14 U.S.qts)]
b)Short in the fuel filter line
8 2-speed solenoid
[Main ECU]
2-speed SOL
a)2-speed solenoid line short
9
AUX1 knob
[Main ECU]
AUX1 knob
a)AUX1 knob connector disconnected
b)Break or short in harness
AUX1 right SOL
[Main ECU]
AUX1 right SOL
a)AUX1 right solenoid connector disconnected
b)Break or short in harness
AUX1 left SOL
[Main ECU]
AUX1 left solenoid
a)AUX1 left solenoid connector disconnected
b)Break or short in harness
KiSC issued 08, 2015 A