Questions and Answers

  • D
    Donna HoSep 10, 2025
    Why is the boom, arm, bucket, drive, swing and dozer power too low on my Kubota U35-4?
    • R
      richardclarkSep 10, 2025
      If the boom, arm, bucket, drive, swing, and dozer power is too low on your Kubota Excavators, it could be due to a low hydraulic oil level, requiring you to add oil. Another possibility is leakages in the hoses and/or joints, which would necessitate replacing the hose or joint.
  • R
    richard67Aug 22, 2025
    Why is the pressurizer on my Kubota U35-4 Excavators running at full speed and noisy?
    • H
      Harry HuffAug 22, 2025
      The pressurizer might be running at full speed and noisy due to several reasons: * The filter may be blocked, requiring service. * A door or window might be open; ensure they are securely shut. * The cabin sealing capacity might be inadequate; perform a pressure test and seal any leak points. * The sense pipe could be blocked; ensure it is clear and not bent. * The internal sensor could be damaged, requiring controller replacement.
  • J
    Jennifer KentAug 25, 2025
    What to do if my Kubota Excavators displays a low pressure alarm?
    • R
      Ryan DavisAug 25, 2025
      If the Kubota Excavators displays a low pressure alarm, it could be due to several reasons: * A door or window is open. Ensure all doors and windows are securely shut. * The cabin sealing capacity is not adequate. Perform a pressure test procedure and rectify the cab sealing. * The pressurizer is not operating. Ensure the correct voltage (12v or 24v) is supplied to the pressurizer motor pin A. * The pressure sense tube is blocked. Unplug it at the monitor and ensure clear flow to the exterior of the cabin. * There is a poor power supply. Check the 20A mains fuse and ensure the correct voltage. * There is a poor earth connection. Check the earth continuity at motor pin B.
  • H
    hchaseAug 26, 2025
    What to do if filter blocking quickly in Kubota U35-4 Excavators?
    • N
      Nicholas AdkinsAug 26, 2025
      If the filter is blocking quickly, it may be due to defective cabin sealing. Perform a pressure test procedure and seal any leak points as required. Alternatively, the pre-cleaner may have failed; check its operation and replace it if necessary.
  • M
    Miranda DeanAug 27, 2025
    What to do if my Kubota Excavators controller showing 0.0 pressure?
    • A
      Adam ColemanAug 28, 2025
      If the controller is showing 0.0 pressure, the fresh air filter may be blocked. Check the filter condition and replace it if required.
  • J
    joe33Aug 29, 2025
    What to do if my Kubota Excavators display is blank?
    • K
      Kathryn HernandezAug 29, 2025
      If the display is blank, check the mains supply fuse and correct voltage, as there may be a poor power supply. Alternatively, the controller may have failed, requiring monitor replacement.
  • X
    xfrenchSep 18, 2025
    What does it mean if the system indicator light flashes on Kubota Excavators?
    • D
      Dennis MasonSep 18, 2025
      If the system indicator light flashes on your Kubota Excavators, it indicates that a fuse in the fuse box is defective and needs to be replaced.
  • R
    rossvargasSep 12, 2025
    Why is my Kubota U35-4 Excavators overheating and the water temperature is in the red zone?
    • D
      Dawn KaneSep 12, 2025
      If your Kubota Excavators is overheating, with the water temperature in the red zone, several factors could be responsible. A damaged cylinder head gasket causing coolant loss requires replacement. Low engine oil level needs to be corrected by filling to the prescribed level. Maladjustment of fuel injection requires readjustment of ignition timing. Finally, the use of poor fuel necessitates switching to the prescribed fuel.
  • A
    Andrew NolanSep 8, 2025
    What to do if Kubota U35-4 engine suddenly stops?
    • J
      Joseph ClarkSep 8, 2025
      If your Kubota Excavators engine suddenly stops, check the fuel level and add fuel if necessary. Also, purge the fuel system.
  • W
    Wendy MillerSep 5, 2025
    What to do if Kubota U35-4 water temperature is in red zone (Overheating)?
    • H
      htuckerSep 5, 2025
      If your Kubota Excavators is overheating, several issues could be the cause. It could be due to a defective water pump seal, which needs replacement. A worn or torn V-belt should be adjusted or replaced. A defective thermostat also requires replacement. Low coolant level needs to be addressed by filling to the prescribed level. Clogged radiator grill or fins should be cleaned. Coolant contaminated with rust requires replacement and the addition of anti-rust. A defective radiator cap should be replaced. Corroded coolant pipes should be cleaned. Finally, continuous operation under full load requires a reduction in load.

Summary

SAFE OPERATION

BEFORE OPERATION

Pre-operation checks and understanding limitations.

OPERATING THE EXCAVATOR

Safe procedures for operating the excavator and avoiding hazards.

DANGER, WARNING AND CAUTION LABELS

Identification and meaning of safety labels on the machine.

CHECKS BEFORE START

WARNINGS AND INDICATORS

Understanding warning lamps, error messages, and indicators.

HANDLING THE SAFETY DEVICES

Proper use of safety features like the pilot control lock lever.

OPERATION OF THE ENGINE

EXCAVATOR OPERATION

MAINTENANCE

REGULAR CHECKS AND MAINTENANCE WORK

TROUBLESHOOTING

OPERATION UNDER COLD WEATHER CONDITIONS

Kubota U35-4 Specifications

General IconGeneral
BrandKubota
ModelU35-4
CategoryExcavators
LanguageEnglish

Related product manuals