EasyManua.ls Logo

Kubota WG972 E3 - Combustion and Cooling Air Requirements (at 25 Deg.C and 1000 Hpa)

Kubota WG972 E3
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-6
[3] Combustion and cooling air requirements
(At 25 deg.C and 1000 hPa)
NOTE
Cooling fan and fan pulley specifications (Cooling fan Part No. 15881-7411)
Conversion rates
1 L=61.0237 in
3
=0.035315 ft
3
1 ft
3
=28.3168 L
1 L/sec=3.6 m
3
/h=2.1189 ft
3
/min
Model Fuel Output
Engine Speed (min
-1
(rpm))
2000 2400 2800 3200 3600
WG752
Gasoline
Combus tion a nd
cooling air requirements
L/sec 369.9 431.3 491.2 567.4 670.1
m
3
/h 1331.6 1552.8 1768.3 2042.5 2412.5
in
3
/sec 22572 26322 29974 34622 40894
ft
3
/min 783.7 913.8 1040.6 1202.0 1419.7
LPG
Co mbus tion a nd
cooling air requirements
L/sec 359.1 425.8 491.6 564.5 689.9
m
3
/h 1292.9 1532.8 1769.8 2032.4 2483.8
in
3
/sec 21916 25982 30000 34450 42102
ft
3
/min 760.9 902.0 1041.5 1196.0 1461.7
Model Fuel Output
Engine Speed (min
-1
(rpm))
2000 2400 2800 3200 3600
WG972
Gasoline
Co mbus tion a nd
cooling air requirements
L/sec 584.9 753.6 843.8 855.7 789.3
m
3
/h 2105.5 2712.9 3037.7 3080.5 2841.5
in
3
/sec 35690 45986 51492 52217 48165
ft
3
/min 1239.1 1596.5 1787.7 1812.9 1672.2
LPG
Co mbus tion a nd
cooling air requirements
L/sec 482.8 602.2 704.7 755.0 745.7
m
3
/h 1738.0 2168.1 2537.1 2718.1 2684.5
in
3
/sec 29461 36751 43005 46074 45504
ft
3
/min 1022.8 1275.9 1493.1 1599.6 1579.8
DG972 NG
Co mbus tion a nd
cooling air requirements
L/sec 433.0 533.1 617.5 652.8 600.1
m
3
/h 1558.7 1919.2 2222.9 2350.1 2160.4
in
3
/sec 26422 32532 37680 39835 36620
ft
3
/min 917.3 1129.4 1308.2 1383.0 1271.4
Item
Fan diameter 300 mm (11.81 in)
No. of blade and type of shape 4, S type
Diameter of fan driving pulley 100 mm (3.94 in)
Diameter of fan pulley 84 mm (3.31 in)

Table of Contents