FC3160TCD-3560TCD-4060TCD
126
12. - Troubleshooting guide
KN284DGB B
Mower conditioner
Impossible to decrease or
increase the mowing unit
ground pressure
sufficiently.
Soil build-up on the
machine.
and
Maximum ground
pressure reduction.
Adjust torsion bars of the
ground pressure system.
(See maintenance and
storage chapter)
Insufficient ground
pressure.
and
Minimum ground pressure
reduction.
The rotor is no longer
driven.
The safety system shear
bolt has sheared.
Replace screw. (See
maintenance and storage
chapter)
Wide spreading of poor
quality.
Incorrect cover position.
Tip cover over the wide
spreading device.
Side ejections.
Incorrect conditioner
feeding.
Fit lifters supplied with the
machine on the two disks
placed directly next to the
cones.
See chapter: Maintenance
/ Maintenance / Fitting of
the lifters