EasyManua.ls Logo

KUHN AXIS 30.1 - Calibration of the Border Spreading Unit GSE (Optional Equipment); (Only for AXIS 20.1, AXIS 30.1, AXIS 40.1); Calibration of the Border Spreading Unit

KUHN AXIS 30.1
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standard operating procedure (all models)
61
8
AXIS-GENERAL
8. 8 Calibration of the border spreading unit GSE (optional equipment)
(only for AXIS 20.1, AXIS 30.1, AXIS 40.1)
The border spreading unit is used for limiting the spreading width (either towards
the right or left) in the range between approx. 0.5 m and 2 m from the middle of
the tractor track towards the outer field boundary.
The metering slide that points to the field edge is closed.
Fold the border spreading unit downwards for boundary spreading.
The border spreading unit must be hinged up again before two-sided spread-
ing.
8.8.1 Calibration of the border spreading unit
Figure 8.20: Calibration of the border spreading unit
[1] Screw nut
[2] Indicator
[3] Number scale
[4] Hand grip
1. Refer to the assembly instruction manual for the correct position of the
indicator [2].
2. Release the 2 screw nuts [1].
3. Move the number scale [3] till the indicator shows the intended value. Use the
hand grip [4].
4. Put on and tighten the screw nuts [1].
NOTICE
The settings for the border spreading unit refer to the spreading disc working
towards the inside of the field.

Table of Contents