Troubleshooting
7-6
Pitchbend (left) Wheel
Moving the left wheel will trigger a display similar to this:
With the wheel rolled all the way forward, the Value reading should be less than 5; rolled all
the way back, it should be more than 123. When released, it should spring to a value
between 59 and 67 inclusive.
If it is indeed 63, then “CENTER” will also be displayed which indicates perfect centering of
the wheel mechanism. However any value between 59 and 67 inclusive is OK.
Modulation (right) Wheel
Moving the right wheel will trigger a display similar to this:
With the wheel rolled all the way forward, the value should be no greater than 1. When
rolled all the way back, it should be no less than 126.
Data Slider
When the data slider is moved, the display should change to something like:
Moving the data slider downward should produce values down to zero. Moving it upward
should produce values up to 127.
Control Pedal
When a control pedal is plugged into the CC Pedal jack and moved, the display should
change to something like:
When the pedal is moved, the values should change from 0 or 1 to 126 or 127. See the
Control Pedal Problems section above if the pedal’s range is less than this. Also check the
value reading when the CC Pedal plug is pulled out, it should change to 126 or 127.
CC PEDAL
VALUE 56
DATA SLIDE
VALUE 119
MODULATION
VALUE 76
PITCH BEND
VALUE 101