Chapter 2
Diagnostics
Diagnostic Tests
The following lists the diagnostic tests available for the PC3x.
Note: Throughout this manual many references are made to the MARA 1 and MARA 2 ICs. For
service personnel unfamiliar with the PC3x, MARA is the name given to the two Kurzweil
Custom Sound ICs.
SDRAM Refresh
Flash Memory
MARA Validity Check
MARA Communications
Exp DIMM Check
MIDI UART
External Card
MARA Delay RAM
MARA Sound ROM
Audio Output
Warning: If possible, save all user programs and setups before entering diagnostics or
performing maintenance or repair. For instructions, refer to Saving User Data in Chapter 4,
page 4-2.
Entering Diagnostics
1. Apply power to the unit. When the ****Welcome to the Kurzweil PC3**** message appears in
the LCD, quickly press and release the Exit button. The LCD should display the following:
Figure 2-1 LCD example, Boot Loader
2. Press the soft button below RUN DIAGS in the LCD.
PC3 Boot Loader Version X.XX
RUN UPDATE RUN SYSTEM FILE
PC3 IMAGE DIAGS RESET UTILITIES