Select a location close to the vessel's centerline and midships, within temperature limits.
Ensure the mounting surface is flat, level, and strong enough for the antenna's weight and forces.
Details minimum requirements for pedestal height, tube OD, wall thickness, brace height, OD, thickness, and angle.
Select a location well above passenger/crew areas to minimize RF exposure risk.
Ensure the antenna has a clear view of the sky for optimal satellite signal communication.
Maintain proper distance from radar and high-power radio transmitters to prevent damage or performance loss.
Maintain minimum distances from GPS, cellular, VHF antennas, and compasses to avoid interference.
Mount the BDU in a standard equipment rack, ensuring 1U space and proper support.
Secure the BDU on a shelf, ensuring it is stable and accessible for user operation.
Route the antenna cable through the access hole, ensuring service loops and proper bend radius.
Clean and connect the N-type connector, apply silicone grease, and hand-tighten securely.
Connect and configure an NMEA 0183 talker for vessel heading input at 4800 baud.
Connect the BDU to the vessel's NMEA 2000 network backbone using a T-connector.
Details requirements for 3-wire single-phase AC power and considerations for two-phase systems.
Explains the critical importance of proper grounding to prevent damage and electric shock.
Guides users on accessing the setup wizard via wireless or wired Ethernet connections.
Outlines the steps in the wizard for system configuration, including passwords and network settings.
Allows setting a read-only guest account password for terminal status and configurations.
Provides options to change IP address, subnet mask, and DHCP mode for network configuration.
Allows configuration of SSID, band, channel, and password for the built-in Wi-Fi access point.
Configures the LAN settings for the BDU's Ethernet ports and built-in Wi-Fi.
Allows selection of shore-based Wi-Fi networks for internet connectivity and advanced Wi-Fi settings.
Describes how to set up a network device with a static IP address for direct internet access.
Explains connecting external VoIP devices for additional phone lines or crew calling functionality.
Declares compliance with EU Directive 2014/53/EU for radio equipment.
States compliance with FCC Part 15 rules for radiated and conducted emissions.