EasyManuals Logo

Kwikset Smartcode 888 User Manual

Kwikset Smartcode 888
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
© 2016 Spectrum Brands, Inc.
Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34
will program the last 4 bytes of the SKU. Most printable values are accepted for the set
command.
When getting the SKU, it must be done in two get commands, one for each parameter.
The order of getting the SKU does not matter.
Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34
will retrieve the last 4 bytes of the SKU.
2.2 Configuration Parameter 35
Parameter Name: Interior Status LED control
Data Length: 1 byte
Default Values: 1 (enabled)
Possible Values: 1 – enabled, 0 – disabled
Description:
The configuration parameter 35 is a one byte field that will allow the user to get / set the
value for the Interior Status LED control. The value of 0 means that the setting is
disabled; whereas the value of 1 means that the setting is enabled.
Sending a set command with the default field set to 1 will cause the control to revert back
to its factory default setting.
2.3 Configuration Parameter 36
Parameter Name: Auto-lock Feature Control
Data Length: 2 bytes
Default Values: Byte 1: 0 – disabled; Byte 2: 0x1E (HEX) (30 seconds)
Possible Values: Byte 1: 1 – enabled, 0 – disabled
Byte 2: 30, 60, 90, 120, 180 (all in seconds)
Description:
The configuration parameter 36 uses 2 bytes that will allow the user to get / set the value
for the Auto Lock feature and timing for that feature. The first byte will be the
enable/disable byte. The value of 0 means that the setting is disabled; whereas the value
of 1 means that the setting is enabled. The next two bytes will be the timing for the Auto
Lock feature and should contain the number of seconds before the Auto Lock will occur.
The valid values are: 0 (default – 30 seconds), 30, 60, 90, 120, 180. For example, setting
the auto lock feature for 60 seconds, the two timing bytes should be: 0x003C.
Sending a set command with the default field set to 1 will cause the control to revert back
to its factory default settings.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kwikset Smartcode 888 and is the answer not in the manual?

Kwikset Smartcode 888 Specifications

General IconGeneral
Lock TypeElectronic Deadbolt
KeypadYes
KeywayKW1
Battery4 AA batteries
Finish OptionsSatin Nickel, Venetian Bronze, Polished Brass
CompatibilityZ-Wave
User CodesUp to 30
Power SourceBattery
Re-key TechnologySmartKey Security
ANSI GradeGrade 2
Backup PowerNo
Lock MechanismMotorized Deadbolt
Auto-LockYes
Voice ControlNo
AlarmNo
Remote AccessYes, with compatible smart home system

Related product manuals