EasyManua.ls Logo

Kyocera DF-9100 - Page 374

Kyocera DF-9100
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-44
Machine transportation after setup > Procedure for the main unit transportation (Truck transportation)
[CONFIDENTIAL]
41
Remove 2 screws.
42
Hold and remove the protective cap [A] in the direction of arrow.
Please make sure not to touch the print head by the protective cap.
43
Push the treatment unit [A] in the inside of the main unit.
44
Please make sure to check the position of the screw [B] located at bottom side of the
treatment unit [A].
In case of turning power on without removing the cap unit, the belt of the image conveying unit, caps in the treatment unit
and the wipe section mights get broken.
C2120: Treatment cap HP sensor error (See page 5-3 for the corrective action of service call)
Clean the cap unit with Alfa wipes and deionized water, and keep it for other transportation in future.
[A]
[A]
[B]

Table of Contents

Related product manuals